2001 Solar Cell Analysis Data - Direct S...

Dave Hrynkiw
July 12, 2007
  Overview
  At Solarbotics, we've been getting quite a few questions regarding the "real-world" performance of our solarcells. Although we do have the official Panasonic Sunceram datasheets, it is written in a quite technical manner and does not include practical design data. With that in mind, we have generated the following - the first of three sets of data for use by the BEAM community. This first set of data is taken with direct-sunlight performance in mind. The second and third sets will be measured under halogen and incandescent lighting (stay tuned...).
  Data Acquisition Procedure
  Solarcell voltage across resistance values recorded on June 20 between 13:07 and 13:25. Solarcell capacitor charging values for capacitors between 1000uF and 4700uF recorded on June 22 Between 13:30 and 14:00.Solarcell capacitor charging values for capacitors between .047F and 1.0F recorded on June 25 between 13:25 and 14:10.Summer solstice on June 21, maximum sunlight at 13:37 (located in Calgary, Alberta, Canada).Testing apparatus consists of a basic stamp 2 for data logging and a ADC0831 chip for analog to digital conversion, 8 bit accuracy (0.02 volt resolution). When testing multiple resistive loads, relays were used to switch the load across the solarcell with a 200ms settle time. The basic stamp controlled sequencing and data logging by measuring the voltage across each switched load.When testing the charge rate of multiple capacitors, the capacitor was shorted by a relay for a period of five seconds, then released to charge by the solarcell. Voltage readings were taken between .2 and 5 seconds, depending on estimated total charge time. An 80% open voltage line is also indicated on the graphs.
 
  Charge Times sorted by Solar Cell
 
  • SC2422 charging CP.33F, 2xCP.33F in series, CP1F and 2xCP1F in series (GIF)

  • SC2433 charging CP.33F, 2xCP.33F in series, CP1F and CP1F in series (GIF)

  • SC3733 charging CP.33F, 2xCP.33F in series, CP1F and CP1F in series (GIF)

  • SC3766 charging CP1000uF, CP3300uF (actual and estimate), CP4700uF (actual and estimate) (GIF)

  • 10xSCPD charging CP1000uF, CP3300uF (actual and estimate), CP4700uF (actual and estimate) (GIF)

  • 10xSCPD charging CP.047F Tokin capacitor (GIF)

 
  Charge Times sorted by Capacitor
 
  • CP.33F charged by SC2422, SC2433 and SC3733 (GIF)

  • 2xCP.33F in series charged by SC2422, SC2433 and SC3733 (GIF)

  • CP1F charged by SC2422, SC2433 and SC3733 (GIF)

  • 2xCP1F charged by SC2422, SC2433 and SC3733 (GIF)

 
  Solar Cell output under Resistance
 
  • Voltage vs Resistance for SC2422, SC2433, SC3733, SC3766 and SCPDx10 (GIF)

  • Current vs Resistance for SC2422, SC2433, SC3733, SC3766 and SCPDx10 (GIF)

  • Power vs Resistance for SC2422, SC2433, SC3733, SC3766 and SCPDx10 (GIF)

 
  Complete Data Sheet Download
  For those of you who would rather have access to the complete data sheets and charts for the 2001 Solar Cell Analysis, we provide this information in the Microsoft Excel format.Solarcell Data Sheet A - 88KB
Solarcell Data Sheet B - 388KB
 
  Disclaimer:  
  Although the information is provided freely, we request that any reproduction or reference to the above data be included with proper accreditation to Solarbotics Ltd. Additionally, although we have performed these tests in good faith, we do not and cannot warrantee this data in any way.

MORE POSTS

June 6, 2002
New Inexpensive Gearmotors!

Woohoo! We're thrilled to announce that Solarbotics is the exclusive importer for these Mark Tilden-designed gearmotors. 224:1 ratio, lots of torque, modifiable - these are idea for high-torque applications like walkers and turbots. Check the "New Items" listing on the left side for details, or view them directly here: GM2 (offset) or GM3 (90 degree) […]

April 26, 2010
Sumovore with Bad Attitude?

Has anyone else have reports of attitude problems with the Sumovore?

September 13, 2005
SCC3733 Solarcell hacking

Here's a tip submitted by Rick Steenblik regarding hacking our SCC3733 for less voltage, but more current: After using your SCC3733 solar cells for a couple of bots I noticed that they can be altered to provide about 3.3v at 80ma (in full sun) by cutting the bus connector on the back to electrically separate […]

July 31, 2013
Wednesday Cool Links: Theremin Goggles, ...

Shooting analog pictures, shooting bullets underwater, shooting… theremin noises from goggles, shooting… human-powered helicopters! if that doesn’t make any sense, see the links below: Steampunk theremin goggles A wicked build by [Sarah] - theremin steampunk goggles. Photo sensor  will feel the amount of light and the slider would adjust the pitch of the sound produced. Check […]

1 2 3 252
Solarbotics Ltd Logo
Solarbotics has been operating for more than 25 years, bringing electronics know-how and supplies to both the electronics professional and hobbyist. We'll be happy to help you too!

Solarbotics, Ltd. is not responsible for misprints or errors on product prices or information. For more information, please see our Terms and Conditions.

Warning: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
Please visit www.P65Warnings.ca.gov for more information. This item was manufactured prior to August 31, 2018.

Copyright © 2024 Solarbotics Ltd. All Rights Reserved
cart